D10, D50, and D90: Reading Earthworm Peptide Particle-Size Reports
D10, D50, and D90: Reading Earthworm Peptide Particle-Size Reports
D10, D50, and D90 show where the fine end, midpoint, and coarse end of a cumulative particle-size distribution fall. Before comparing reports, check whether the values are based on volume, mass, or particle count. A laser diffraction report commonly gives volume percentiles, written Dv10, Dv50, and Dv90. Dv90 is the diameter below which 90% of the measured particle volume falls. A report can therefore show a stable Dv50 while a shift in Dv90 points to a change at the coarse end.
When sourcing earthworm peptide powder, use these figures to decide whether a sample merits a closer look for your feeding, blending, or dispersion process. Start by establishing what the laboratory measured and how it prepared the powder. Then compare the whole distribution with a qualified sample and check the property that matters in your process.
Read the percentiles on the same basis
A cumulative distribution adds up the amount of material at or below each measured size. With a volume distribution, a large particle contributes more to the total than a small particle. With a number distribution, each counted particle contributes equally. The same physical sample can therefore show a lower median by number than by volume. Look for the distribution basis next to the percentile names or on the chart axis, particularly if the certificate abbreviates the labels to D10, D50, and D90.
| Result | What the result shows | Question to ask when it changes |
|---|---|---|
| Dv10 | The diameter below which 10% of measured particle volume falls. | Did the lower end of the distribution shift, or did the preparation disperse the powder differently? |
| Dv50 | The median diameter by measured particle volume. | Is the middle of the distribution similar to the approved sample? |
| Dv90 | The diameter below which 90% of measured particle volume falls. | Did the coarse end shift, and is there a reason to inspect the full distribution or retained powder? |
For a hypothetical result of Dv10 = 12 µm, Dv50 = 46 µm, and Dv90 = 125 µm, about half the measured particle volume is below 46 µm and about a tenth is above 125 µm. Those are example numbers for reading a report. Actual limits should come from your material and process. Dv90 also leaves the largest tenth by volume undescribed. Ask for the full distribution or a separate coarse fraction measurement if rare, large particles could affect your equipment.
Laser diffraction uses light scattering and an optical model to estimate a distribution of equivalent particle sizes. For an irregular particle, the reported equivalent diameter can differ from the longest dimension seen in a microscope. A sieve separates material by passage through an aperture, so its result also has a different meaning. When two reports come from different measurement principles, keep the results associated with their own methods. ISO 13320:2020, Particle size analysis by laser diffraction. Malvern Panalytical, particle characterization guide.
Check how the powder was dispersed
Laser diffraction can measure a powder dispersed in air or a suspension dispersed in a liquid. The preparation changes which structures reach the measurement zone. A dry dispersion method may preserve some loose clusters at one setting and break them apart at another. In a wet method, the choice of liquid and mixing can affect whether the powder remains suspended, forms clusters, or partly dissolves. Ask the lab which state the method was designed to measure and how it checked that the test represents that state.
The decision depends on the intended application. A process engineer studying the behavior of powder as delivered may care about structures that remain present under normal handling. A developer comparing the underlying dispersed particles may want a method that separates loose clusters consistently. A lab report is easier to use when it states the dispersion approach, the instrument and method revision, and any relevant stability checks during measurement. Malvern Panalytical, laser diffraction and dispersion questions.
| Check | Information to compare | Why it affects the decision |
|---|---|---|
| Material sampled | Grade, lot, sample point, and whether the sample came from the shipped material. | A pilot sample or a portion taken from a single container may represent a different population. |
| Distribution basis | Volume, number, or mass, plus size units. | Percentiles require the same basis before their numerical values can be compared. |
| Dispersion | Wet or dry approach, dispersant if used, and the method revision. | Preparation can change how clusters and soluble material appear in the result. |
| Instrument and model | Model selection, optical inputs where relevant, and equipment identification. | Instrument and analysis choices can change the distribution calculated from the scattering signal. |
| Repeatability | Results for replicate preparations and any consistency criteria. | Variation across preparations helps show whether the reported shift can be distinguished from measurement variation. |
| Distribution shape | Cumulative curve and size-frequency plot from the report. | Three percentiles can miss a secondary peak or a difference outside the reported sizes. |
Look past the median when comparing lots
Imagine an approved sample and a new delivery both have a Dv50 close to 46 µm. The new delivery has a higher Dv90. If sample preparation and method match, a look at the size-frequency plot may show a broad increase at the coarse end or a smaller, separate population. The shape helps you choose the next investigation. Inspect a retained sample to see whether larger structures are visible, then test how those structures behave in the intended process if they could matter there.
A falling Dv10 with a similar Dv50 can also deserve review. It may indicate a shift toward finer material at the lower end, or it may reflect how the sample was dispersed. Review the sampling record, duplicate preparations, and any recent changes to equipment or handling before drawing a production conclusion. If the first and second samples were taken at different stages of handling, document those stages and consider taking new samples at comparable points.
Some reports include a span, calculated as the difference between Dv90 and Dv10 divided by Dv50 when all three values are on the same basis. It gives a compact way to trend relative breadth. Two reports can have similar spans and very different curve shapes, so keep the graph in the lot file. When a change matters, compare the curves and the material side by side.
Pair size results with the process that matters
A powder handling team may use a size report as one input to a feed trial. Two lots with similar distributions can behave differently if moisture, particle shape, or surface conditions differ. If the decision is about feeding, measure how the material moves through the relevant equipment. If it is about blending, collect evidence that the selected mixing procedure gives the required consistency. Particle-size data can help investigate an issue once a difference has been observed.
A beverage or premix developer may be interested in what happens during wetting and mixing. Ask for an application trial with the intended liquid, mixing conditions, and time points, and record the performance measure that matters to the formula. Dry powder size, wet dispersion size, and the molecular weight of peptides describe different features. Laser diffraction reports the equivalent size of dispersed particles or clusters. A molecular weight profile describes molecules or fractions measured using a suitable separation or characterization method.
If a report uses a mesh designation, request the aperture, sieve method, and the retained or passing fraction. A mesh designation can help answer a particular oversize question. Its result depends on particle shape, the way particles pass through the opening, and the operating procedure. A mesh number by itself cannot supply the three volume percentiles of a laser diffraction report.
Make the sample traceable to the powder you will use
A precision instrument measures the portion that reaches its sample compartment. In a delivered lot, particle sizes can be unevenly distributed across containers or within one container after handling. Ask how the test portion was taken and what it represents. A scoop drawn from the top of one bag may be useful to investigate that bag. For lot acceptance, establish a plan that covers the units and locations relevant to the decision, and record any pooling before the lab divides the sample.
For an initial comparison, consider retaining separate portions if the concern is unevenness within the shipment. Combining them may yield a useful picture of average material while masking a difference between locations. If the concern is consistency between labs, distribute comparable splits from a representative portion and document how they were prepared. Sharing one sample identifier across all reports makes it easier to distinguish between-lab variation from differences in the material collected.
Ask the lab to retain the original distribution export and preparation notes alongside the certificate. If a later test flags a change at the coarse end, the earlier curves allow a direct comparison on the same basis. Retention conditions also matter when moisture or handling might change the structures present in the powder. Record when the material was opened, how it was kept, and whether the retest used the original retained portion or newly sampled material.
Set a lot review rule from measured evidence
Start with representative samples from the grade and packing format you plan to purchase. Ask the supplier and your laboratory to test comparable portions of the same material, then look at the variation across preparations and across lots. Retain the complete reports from any sample that performs satisfactorily in your process. Those records let you compare a later shipment against an actual reference, with a record of how the reference was measured.
If coarse particles are the practical concern, decide whether Dv90, a reported fraction above a chosen diameter, or a sieve result would address it most directly. Where performance is sensitive to fines, choose a lower-end indicator that your lab can repeat reliably. A limit should account for sampling and analytical variation as well as the performance of the powder. Document the test method, revision, units, distribution basis, and how you will handle values near the limit.
For a lab transfer, ask both laboratories to compare retained portions from several lots and send the underlying distributions. An instrument change may affect a tail of the curve even when the median remains close. Record any differences before putting the second laboratory’s figures into the same trend chart. Where acceptance decisions could differ, agree with the supplier about which test governs the decision and how a dispute will be resolved.
When a delivery appears outside the historical range, review the original result alongside the sampling record and method revision. A retest from a new preparation can help distinguish a preparation issue from a repeatable difference. If the first sample was not representative, use the agreed resampling procedure. Keep the original and follow-up reports together so the final decision can be reconstructed.
FAQ
What is the difference between D50 and average particle size?
D50 is the median of the stated cumulative distribution. For Dv50, half the measured volume is below the stated diameter. A mean uses a different calculation and can respond differently to the fine or coarse end of the distribution. Ask for the reported statistic and its basis.
Does Dv90 tell me the largest particle in a powder?
Dv90 leaves roughly 10% of measured particle volume above the stated diameter. Request a full distribution or an agreed coarse fraction test if particles above a particular size can affect the process.
Can I compare a dry laser diffraction result with a wet one?
Compare the reports after reviewing how each method disperses the same representative material. Treat a difference as method dependent until paired measurements establish how the two procedures relate for your grade and sample conditions.
What should I do if Dv50 matches but Dv90 has increased?
Check the method revision and sampling history, ask for the full distributions and replicate results, and inspect the retained powder. If the shift is repeatable, test the relevant handling or formulation step before deciding how to treat the lot.
What belongs on a particle-size specification?
Specify the grade, sample, method and revision, units, distribution basis, and the percentiles or size fractions that relate to your process. Agree on who reviews a result near the limit and how retests or method changes are handled.
Send Your Ingredient Inquiry
Share the grade and application you are evaluating, along with the particle-size report or the process problem you are trying to resolve. Include the dispersion method, distribution basis, and the percentile or size fraction you need reviewed. The Venacorebio team can discuss the sample and documentation relevant to your inquiry.